8 years 6 months ago #6083 by Dr-DJet
Replied by Dr-DJet on topic MAP sensor Pn 0 280 100 010 Leaking
Hi Stig,

that's great news !

Just a small improvment proposal: I recommend you to swap your ECU from 0 280 000 009 to 0 280 000 017. That also has the electronic thermo time switch but adds the idle-run potentiometer. 0 280 100 034 does not work as it misses thermo time switch and - less important - over-run shutoff.

Viele Schraubergrüße - best regards, Dr-DJet Volker
Alles für den Mercedes-Benz R/C 107 und W116 in der SLpedia Sternzeit 107
Workshops Heizung/Klima 10.5.(HU), D-Jetronic 28.6.(F),20.9.(ER), K-Jetronic 31.5.(ER),23.8.(F)

This image is hidden for guests.
Please log in or register to see it.

The following user(s) said Thank You: s.bunzel

Please Log in or Create an account to join the conversation.

  • s.bunzel
  • Topic Author
  • Offline
  • New Member
  • New Member
More
8 years 6 months ago #6085 by s.bunzel
Replied by s.bunzel on topic MAP sensor Pn 0 280 100 010 Leaking
Hi Volker

Thanks for the good advice :)

I already found a 0 280 000 017 one at scrap yard not far from my home.

Best regards
Stig

Please Log in or Create an account to join the conversation.

  • s.bunzel
  • Topic Author
  • Offline
  • New Member
  • New Member
More
8 years 5 months ago #6117 by s.bunzel
Replied by s.bunzel on topic MAP sensor Pn 0 280 100 010 Leaking
Now I got the 0 280 000 017 ECU! cheap :) :)
Now I just need to test it!

Please Log in or Create an account to join the conversation.

  • Dr-DJet
  • Offline
  • Moderator
  • Moderator
  • Dr-DJet repariert und sammelt alles! :-)
More
8 years 5 months ago - 8 years 5 months ago #6118 by Dr-DJet
Replied by Dr-DJet on topic MAP sensor Pn 0 280 100 010 Leaking
Hi Stig,

that is great. Now you have not only over-run shutoff but also the possibility to adjust idle-run CO. Plus it has the electronic thermo time switch integrated.

Viele Schraubergrüße - best regards, Dr-DJet Volker
Alles für den Mercedes-Benz R/C 107 und W116 in der SLpedia Sternzeit 107