- Posts: 17
- Thank you received: 0
Kontaktzündungen, kontaktgesteuerte Transistorzündungen, Induktions- und Hallgeber gesteuerte Transistorzündugen
Ignition timing for my MB
- TomasLT
-
Topic Author
- Offline
- New Member
-
Less
More
6 years 11 months ago #9201
by TomasLT
engine shut off on drive was created by TomasLT
Hello Volker,
My questions is regarding idle timing value. In a workshop manual it is said - TDC 0°+/-2° at idle with vacuum.
On topics I found - (1. Is it a European engine with European distributor? If so, then set to 10 ° before TDC at start-up speed without negative pressure. )
what should be correct timing value at idle in my case ?
Ignition distributor: 0 231 403 001 , EU model, engine 116
timing test values I have:
30° @ 3000/min without vacuum
19° @ 1500/min without vacuum
10° at idle with vacuum
regards,
Tomas
My questions is regarding idle timing value. In a workshop manual it is said - TDC 0°+/-2° at idle with vacuum.
On topics I found - (1. Is it a European engine with European distributor? If so, then set to 10 ° before TDC at start-up speed without negative pressure. )
what should be correct timing value at idle in my case ?
Ignition distributor: 0 231 403 001 , EU model, engine 116
timing test values I have:
30° @ 3000/min without vacuum
19° @ 1500/min without vacuum
10° at idle with vacuum
regards,
Tomas
Please Log in or Create an account to join the conversation.
- Dr-DJet
-
- Away
- Moderator
-
- Dr-DJet repariert und sammelt alles! :-)
6 years 11 months ago #9203
by Dr-DJet
Viele Schraubergrüße - best regards, Dr-DJet Volker
Alles für den Mercedes-Benz R/C 107 und W116 in der SLpedia Sternzeit 107
Workshops Heizung/Klima 10.5.(HU), D-Jetronic 28.6.(F),20.9.(ER), K-Jetronic 31.5.(ER),23.8.(F)
This image is hidden for guests.
Replied by Dr-DJet on topic engine shut off on drive
Hi Tomas,
I have moved your thread into a new topic as it had nothing to do with David's issues.
You will find the answer to your question in menu 107 SL workshop manual: jetronic.org/de/107sl-wsm/107sl-wsm-cont...-107sl-ri-engc-m116D
Look into chapter 07.5-500 Checking and adjusting dwell and ignition timing
And as you have advance and retard on your vacuum connection, check both.
I have moved your thread into a new topic as it had nothing to do with David's issues.
You will find the answer to your question in menu 107 SL workshop manual: jetronic.org/de/107sl-wsm/107sl-wsm-cont...-107sl-ri-engc-m116D
Look into chapter 07.5-500 Checking and adjusting dwell and ignition timing
And as you have advance and retard on your vacuum connection, check both.
Viele Schraubergrüße - best regards, Dr-DJet Volker
Alles für den Mercedes-Benz R/C 107 und W116 in der SLpedia Sternzeit 107
Workshops Heizung/Klima 10.5.(HU), D-Jetronic 28.6.(F),20.9.(ER), K-Jetronic 31.5.(ER),23.8.(F)
This image is hidden for guests.
Please log in or register to see it.
Please Log in or Create an account to join the conversation.
Time to create page: 0.091 seconds